Tedea Huntleigh 1250 Potted Single Point, Aluminum High-capacity off-center loading load cell accurately weighs loads from 50 to 1000 kg (110.2 to 2205.0 lb) and NTEP approved. Load cells with potted cavities are available for improved performance in damp environments.
These Tedea 1250 cells have a unique humidity resistant protective coating that assures long term stability even under harsh environment and extreme temperatures. 2mv/v, 0.02% total error, 415/350 ohms, 10' 6 cond. cable, anodized aluminum. NTEP 89-054A III S 5,000 div.
The Model 1250 is a popular single point load cell designed for direct mounting of large platforms. The product is a cost effective load cell for use on weighing, bench or floor scale products.
This high accuracy load cell is approved to OIML R60, NTEP and other stringent approval standards. A special humidity resistant protective coating assures long-term stability over the entire compensated temperature range. The two additional sense wires, sample the bridge supply voltage at the load cell. Complete compensation of change in the lead wires resistance, due to temperature change and/or cable extension, is achieved by feeding this voltage into the appropriate electronics. Similar to the Rice Lake Weighing Systems RL1250, Vishay Celtron LOC, and Flintec PCB.
Part Number ...... Model Number ....... Capacity (kg) ...... Capacity (lb)
17478 .................. 1250-I-50 ............... 50kg ................... 100 lb
17469 .................. 1250-I-75 ............... 75kg .................... 150 lb
33711 .................. 1250-I-100 ............ 100kg ................... 200 lb
33712 .................. 1250-I-150 ............ 150kg .................... 300 lb
33713 .................. 1250-I-200 ............. 200kg .................... 400 lb
33714 .................. 1250-I-250 ............. 250kg .................... 500 lb
33715 .................. 1250-I-300 ............. 300kg .................... 600 lb
33716 .................. 1250-I-500 ............. 500kg .................... 1000 lb
33717 .................. 1250-I-635 ............. 635kg .................... 1400 lb
17480 .................. 1250-I-1000 ........... 1000kg .................. 2200 lb
Also available
Non-NTEP with 25 ft potted Load Cell Cable
CAPACITY ..................... PART NUMBER
50 kg (110.3 lb) ............. 40944
75 kg (165.4 lb) ............. 40945
100 kg (220.5 lb) ........... 40946
150 kg (330.7 lb) ........... 32342
200 kg (440.9 lb) ........... 32341
250 kg (551.2 lb) ........... 40947
300 kg (661.4 lb) ........... 32340